UNii I/O Module

With the UNii I/O module for the UNii alarm system, it’s possible to expand the system with wired zones. The version that includes power supply provides the ability to expand outputs as well. Unique feature: the I/O modules come equipped with a location buzzer, making them easy to locate even if they have been mounted above the suspended ceiling, for instance.

  • 2 possible versions
  • Quick and easy installation
  • Built-in buzzer for location determination

Features I/O Module including power supply

Suitable for expansion additional inputs

The UNii I/O module (incl. PSU) in a metal enclosure comes standard with its own power supply. This module is equipped with eight wired zones and six outputs (two relays, two open collector outputs (max. 200mA), a speaker output (8 ohms), and a controlled siren output). The UNii I/O module (incl. PSU) can be expanded with up to 3 input expansion modules, allowing a total of 32 zones to be connected within the enclosure. The UNii I/O module can also be expanded with an output expansion module (max. 1). These are available in a version with 4 relay contacts or 4 open collector outputs (max. 200 mA).

Product specifications I/O Module including power supply

  • 230V-18VAC @ 2.77A, toroidal transformer supply voltage

  • 90 mA normal current drain, maximum 2A

  • 8 inputs

  • 4 (2x relays, 2 open collector 200mA) or 2 outputs (1x speaker, 1x siren)

  • Operating temperature 0 ° to +40 ° C

  • Dimensions 255 x 120 x 400 mm (LxWxH)

  • White colored

  • Weight: 5660 g

  • EN50131 approved (Grade 3)

Features I/O Module excluding power supply

Quick and easy to assemble

The UNii I/O module (excl. PSU) in a compact metal housing does not include a power supply and must be powered through the RS-485 bus. This module is equipped with eight wired zones and two outputs (two open collector outputs, max. 200 mA). The I/O module is quick and easy to install. The UNii I/O module (excl. PSU) can be expanded with one 8-input expansion board to connect a total of 16 zones in the enclosure. The UNii I/O module (excl. PSU) cannot be expanded with additional outputs.

Product specifications I/O Module excluding power supply

  • RS-485 bus power supply

  • 60 mA normal current output

  • 8 inputs and 4 (open collector 200mA) outputs

  • EN50131 approved (Grade 3)

  • Operating temperature 0 ° to +50 ° C

  • Dimensions 177 x 155 x 35 mm (LxWxH)

  • White colored

  • Weight: 2090 g

Additional modules

All expansion modules for inputs and outputs are universally designed and can therefore be used in both the UNii alarm system, the I/O module, and the door controller. This provides a suitable solution for every conceivable situation. This ensures that the right module is always available and prevents unnecessary stock of different components. The modules are mounted using the provided mounting studs and ribbon cable. Just as simple as the UNii itself.

Veeg om meer te bekijken

UNii 8 inputs

UNii 4 relays

UNii 4 OC

8 wired inputs

4 relays, max 30VDC/2A

4 OC outputs, 200mA

Assembly via flat cable

Assembly via flat cable

Assembly via flat cable

Approval: EN 50131-1:2006 (Grade 3)

Approval: EN 50131-1:2006 (Grade 3)

Approval: EN 50131-1:2006 (Grade 3)

Dimensions: 80 x 40 x 10mm

Dimensions: 80 x 40 x 10mm

Dimensions: 80 x 40 x 10mm

UNii Portretfoto's Frank

Frank

Are you interested, or do you have other technical questions?

Contact form

Do you have any questions, comments, or would you like to collaborate with us? Please do not hesitate to contact us.